* Copyright © Linear Technology Corp. 01/09/2007. All rights reserved. * * Note 1: For greater numerical accuracy in transient simulation, decrease* the maximum simulation time step. * * Note 2: This is a simplified model with no shutdown functionality. * * Node List (same as IC): GND IN1 IN2 VOUT OUTRTN V+ .SUBCKT LTC1968 1 2 3 5 6 7 ISUP1 7 1 2.3E-3 GIN2 0 11 VALUE={0.001*ABS(V(10)/(V(5,6)+0.002)*MIN(V(5,6)*4.183+1E-6,ABS(V(10))))} RIN1 10 0 1E3 RIN2 11 13 1.5E5 DS1 13 0 DS CIN1 10 0 1.5E-11 DS3 12 31 DS RIN3 12 11 50 EOUT 20 0 VALUE={ABS(V(11))+0.002+V(6)} ROUT 5 20 1.25E4 COUT 5 6 8.7E-12 GIN1 0 10 22 33 0.001 RIN4 11 0 1E3 EVCC 31 0 VALUE={0.5*V(7,1)-0.750} CIN2 11 0 1E-11 CS1 33 1 8E-13 CS2 22 1 8E-13 DIN1 2 7 DIN DIN2 4 2 DIN DIN3 4 3 DIN DIN4 3 7 DIN RS1 22 2 2E3 RS2 33 3 2E3 RS3 22 33 1E8 .MODEL DIN D (IS=1E-13 RS=0 KF=0 XTI=0) .MODEL DS D (IS=1E-16 RS=0 KF=0 XTI=0) .ENDS LTC1968